| Processing Steps |
- Parameter or Variable: CTD Temperature; Abbreviation: CTDTMP; Unit: °C; Observation type: measured, data synthesis; Sampling instrument: CTD; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Potential temperature; Abbreviation: THETA; Unit: °C; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: CTD Salinity; Abbreviation: CTDSAL; Observation type: measured, data synthesis; Sampling instrument: CTD; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: CTD Salinity with 2QC applied; Abbreviation: CTDSAL_2QC; Observation type: measured, data synthesis; Sampling instrument: CTD; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Potential density anomaly referred to surface; Abbreviation: SIGMA0; Unit: kg m−3; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Potential density anomaly referred to 1000 dbar; Abbreviation: SIGMA1; Unit: kg m−3; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Potential density anomaly referred to 2000 dbar; Abbreviation: SIGMA2; Unit: kg m−3; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Potential density anomaly referred to 3000 dbar; Abbreviation: SIGMA3; Unit: kg m−3; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Potential density anomaly referred to 4000 dbar; Abbreviation: SIGMA4; Unit: kg m−3; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Neutral density; Abbreviation: GAMMA; Unit: kg m−3; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Dissolved Oxygen; Abbreviation: OXYGEN; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: CTD, Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 0 = interpolated, 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Dissolved Oxygen with 2QC applied; Abbreviation: OXYGEN_2QC; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: CTD, Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 0 = interpolated, 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Apparent oxygen utilization; Abbreviation: AOU; Unit: μmol kg−1; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Nitrate (NO3+NO2); Abbreviation: NITRAT; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 0 = interpolated, 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Nitrate (NO3+NO2) with 2QC applied; Abbreviation: NITRAT_2QC; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 0 = interpolated, 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Nitrite; Abbreviation: NITRIT; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 0 = interpolated, 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Silicate; Abbreviation: SILCAT; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 0 = interpolated, 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Silicate with 2QC applied; Abbreviation: SILCAT_2QC; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 0 = interpolated, 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Phosphate; Abbreviation: PHSPHT; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 0 = interpolated, 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Phosphate with 2QC applied; Abbreviation: PHSPHT_2QC; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 0 = interpolated, 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Total Dissolved Inorganic Carbon; Abbreviation: TCARBN; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Total Dissolved Inorganic Carbon with 2QC applied; Abbreviation: TCARBN_2QC; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Total Alkalinity; Abbreviation: ALKALI; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Total Alkalinity with 2QC applied; Abbreviation: ALKALI_2QC; Unit: μmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: pH on the total hydrogen ion scale at 25ºC and 0 dbar of pressure; Abbreviation: PH_TOT_25C; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: pH on the total hydrogen ion scale at 25ºC and 0 dbar of pressure with 2QC applied; Abbreviation: PH_TOT_25C_2QC; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Chlorofluorocarbon 11; Abbreviation: CFC-11; Unit: pmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Partial pressure of CFC-11; Abbreviation: pCFC-11; Unit: ppt; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Chlorofluorocarbon 12; Abbreviation: CFC-12; Unit: pmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Partial pressure of CFC-12; Abbreviation: pCFC-12; Unit: ppt; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Chlorofluorocarbon 113; Abbreviation: CFC113; Unit: pmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Partial pressure of CFC113; Abbreviation: pCFC113; Unit: ppt; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Carbon tetrachloride; Abbreviation: CCL4; Unit: pmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Partial pressure of CCl4; Abbreviation: pCCL4; Unit: ppt; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Sulfur Hexafluoride; Abbreviation: SF6; Unit: fmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Partial pressure of SF6; Abbreviation: pSF6; Unit: ppt; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Tritium (3H); Abbreviation: TRITUM; Unit: TU; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: 3H counting error; Abbreviation: TRITER; Unit: TU; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: δ3He; Abbreviation: DELHE3; Unit: %; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: δ3He counting error; Abbreviation: DELHER; Unit: %; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Helium (He); Abbreviation: HELIUM; Unit: nmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: He counting error; Abbreviation: HELIER; Unit: %; Observation type: calculated; Researcher name: CARIMED Group
- Parameter or Variable: Neon (Ne); Abbreviation: NEON; Unit: nmol kg−1; Observation type: measured, data synthesis; Sampling instrument: Niskin Bottles; Quality flag convention: WOCE quality control flags are used: 2 = good value, 9 = no value; Researcher name: CARIMED Group
- Parameter or Variable: Ne counting error; Abbreviation: NEONER; Unit: nmol kg−1; Observation type: calculated; Researcher name: CARIMED Group
|