  KROHNE OPTIFLUX 5000 Electromagnetic flowmeter measuring surface seawater flow being delivered
  to forward TSG, SVP probe and Turner C6 in bow thruster room. These electromagnetic flowmeters 
  are designed exclusively to measure the flow and conductivity of electrically conductive, 
  liquid media.

  Location: Forward seachest in bow thruster room
  Sample rate: 1 per second

  Example data line:
    flow_krohne_fwd  2014-12-11T20:19:01.7029Z  0.558,5.93,27.38,0.65940

  Field Descriptions:
    Logger ID
    Time Stamp [UTC]
    flow speed [m/s]
    volume flow [l/min]
    coil temperature [C]
    conductivity [S/m]