rad_psp-pir.txt

  Remote Measurements & Research  PSP (Precision Spectral Pyranometer) and PIR (Precision Infrared Radiometer)

  PSP Serial Number: 37668F3
  PIR Serial Number: 37684F3
  Location: top of science control room
  Sample rate: 1 every 10 seconds

  Example data line:
    rad_psp-pir  2014-12-12T01:29:38.2952Z  $WIR20,14/12/12,01:46:30, 175, -418.5, 265.53, 26.31, 26.15, 278.59, 27.9, 10.8

  Field Descriptions:
    Logger ID
    Time Stamp [UTC]
    ID [NMEA-style tag]
    DATE TIME [yy/MM/dd,hh:mm:ss(Note: this time is not synced with external time server so do not use)]
    # [the number of samples that went into the averages]
    PIR [the average voltage from the PIR thermopile,millivolts]
    LW [the computed longwave downwelling irradiance,Wm**2]
    TCASE [the PIR case temperature,C]
    TDOME [the PIR dome temperature,C]
    SW [the computed shortwave downwelling irradiance,Wm**2]
    T-AVR  [the computed shortwave downwelling irradiance,C]
    BATT [the battery voltage after the input diode drop,volts]