1. Water sample parameters

----------------------------------------------------
Number Parameter         Mnemonic   Mnemonic for
                                      expected error
----------------------------------------------------
 1     Salinity          SALNTY
 2     Oxygen            OXYGEN
 3     Silicate          SILCAT     SILUNC *1
 4     Nitrate           NITRAT     NRAUNC *1
 5     Nitrite           NITRIT     NRIUNC *1
 6     Phosphate         PHSPHT     PHPUNC *1
 7     Freon-11          CFC-11
 8     Freon-12          CFC-12
12     14Carbon          DELC14     C14ERR
13     13Carbon          DELC13     C13ERR
22     137Cesium         CS-137
23     Total carbon      TCARBN
24     Total alkalinity  ALKALI
26     pH                PH
27     Freon-113         CFC113
31     Methane           CH4
33     Nitrous oxide     N2O
42     Abundance of      BACT
         bacteria
64     Incubation
81     Particulate       POM
         organic matter
82     15N-Nitrate       15NO3
----------------------------------------------------
*1 Uncertainty of the nutrients data.  
   See nutrients data report for detail.


2. CTDO parameters

------------------------------------------------------------
Parameter                                          Mnemonic
------------------------------------------------------------
Pressure                                           CTDPRS
Temperature                                        CTDTMP
Conductivity                                       CTDCND
Salinity                                           CTDSAL
Oxygen                                             CTDOXY
Oxygen sensor output                               CTDOXV
Optode oxygen                                      OPTOXY
Optode sensor output (raw phase shift)             OPTPHS
Down-cast pressure at the same density
  of the up-cast CTD data                          DWNPRS
Down-cast CTD oxygen at pressure of DWNPRS         DWNOXY *2
Temperature from Deep Ocean Standards Thermometer  SBE35
------------------------------------------------------------
*2 Down-cast CTD oxygen (DWNOXY) is calibrated
   instead of up-cast CTD oxygen (CTDOXY).


3. Quality flags

-----------------------------------------------------------
                 Bottle quality flags
-----------------------------------------------------------
1  = Bottle information unavailable.
2  = No problems noted.
3  = Leaking.
4  = Did not trip correctly.
5  = Not reported.
7  = Unknown problem.
9  = Samples not drawn from this bottle.
-----------------------------------------------------------

-----------------------------------------------------------
             Quality flags for water samples
-----------------------------------------------------------
1  = Smaple for this measurement was drawn from water bottle
     but analysis not received.
2  = Acceptable measurement.
3  = Questionable measurement.
4  = Bad measurement.
5  = Not reported.
6  = Mean of replicate measurements.
9  = Sample not drawn for this measurement from this bottle.
------------------------------------------------------------

------------------------------------------------------------
          Quality flag definitions for CTD data
------------------------------------------------------------
1  = Not calibrated.
2  = Acceptable measurement.
3  = Questionable measurement.
4  = Bad measurement.
5  = Not reported.
6  = Interpolated over >1 dbar interval.
7  = Despiked.
9  = Not sampled.
------------------------------------------------------------