BOTTLE
Ship: RV SARMIENTO DE GAMBOA
Dates: 26 APR - 31 MAY 2014 
Cruise Alias: HOTMIX 
Region: Mediterranean Sea / Atlantic Ocean
EXPOCODE: 29AH20140426
Chief Scientist: ARISTEGUI, Javier
STNNBR				PUB&REP (1)	Data file (1)
CASTNO				PUB&REP (1)	Data file (1)
BTLNBR				PUB&REP (1)	Data file (1)
DATE				PUB&REP (1)	Data file (1)
TIME				PUB&REP (1)	Data file (1)
LATITUDE				PUB&REP (1)	Data file (1)
LONGITUDE				PUB&REP (1)	Data file (1)
CTDPRS	initial units DBAR		PIs M. Emelianov (ICM CSIC)	PUB&REP (1)	Data file (1)
CTDTMP	initial units ITS90		PIs M. Emelianov (ICM CSIC)	PUB&REP (1)	Data file (1)
CTDSAL	initial units PSS78		PIs M. Emelianov (ICM CSIC)	PUB&REP (1)	Data file (1)
SALNTY	initial units PSS78		PIs M. Álvarez (IEO) & M. Emelianov (ICM CSIC)	PUB&REP (1)	Data file (1)
CTDOXY	initial units µMOL/KG		PIs M. Álvarez (IEO)	PUB&REP (1)	Data file (1)
OXYGEN	initial units µMOL/KG		PIs M. Álvarez & H. Sanleón Bartolomé (IEO)	PUB&REP (1)	Data file (1)
SILCAT	initial units µMOL/KG		PIs X.A. Álvarez Salgado (IIM CSIC)	PUB&REP (1)	Data file (1)
NITRATNO3+NO2	initial units µMOL/KG		PIs X.A. Álvarez Salgado (IIM CSIC)	PUB&REP (1)	Data file (1)
NITRIT	not measured or reported			
PHSPHT	initial units µMOL/KG		PIs X.A. Álvarez Salgado (IIM CSIC)	PUB&REP (1)	Data file (1)
TCARBN	initial units µMOL/KG		PIs T. Tanhua (GEOMAR)	PUB&REP (2,3)	Data file (1)
ALKALI	initial units µMOL/KG		PIs M. Álvarez & H. Sanleón Bartolomé (IEO)	PUB&REP (2,3)	Data file (1)
PHTS25P0	initial units Total Scale 25ºC		PIs M. Álvarez & H. Sanleón Bartolomé (IEO)	PUB&REP (2,3)	Data file (1)
CFC12	initial units PMOL/KG		PIs T. Tanhua (GEOMAR)	PUB&REP (1)	Data file (1)
SF6	initial units FMOL/KG		PIs T. Tanhua (GEOMAR)	PUB&REP (1)	Data file (1)

Reports & publications: 
(1)	Informe Campaña HOTMIX.pdf
(2)	Report HotMix_2014_CO2_CDIAC.pdf
(3)	Fajar N.M., M.I. García-Ibáñez, H. SanLeón-Bartolomé, M. Álvarez, and F.F. Pérez (2015). Spectrophotometric Measurements of the Carbonate Ion Concentration: 
Aragonite Saturation States in the Mediterranean Sea and Atlantic Ocean. Environ. Sci. Technol., 2015, 49 (19), pp 11679–11687, DOI: 10.1021/acs.est.5b03033

Data files: 
(1)	Provided in CARIMED

Carbonate system methods
Alkalinity:
Samples for alkalinity determination were collected in 600mL borosilicate bottles and were analysed within one day after sampling. Samples were analysed 
following the double end point potentiometric technique by Pérez and Fraga (Mar. Chem., 1987) and Pérez et al. (CC.MM., 2000). Measurements of CRM were 
performed in order to control the accuracy of the alkalinity measurements; the pH as measured by the electrode was corrected to obtain the closest mean 
alkalinity to the CRM; the pH correction was never larger than 0.05. The precision of the alkalinity measurements was better than ±0.6 μmol kg−1  determined 
from duplicate Niskin bottles, and the accuracy of the alkalinity measurements (i.e. including sampling errors) is determined to be 1 μmol kg−1 . Additionally, 
the daily drift of the system was determined by regular measurements of a substandard (surface seawater); this drift was always very low. The precision of the 
analysis was ± 0.6 µmol/kg  and the accuracy was determined to be 1 µmol/kg . Taken from Report (2) and publication (3).

pH:
pH was measured in cylindrical optical glass 10-cm pathlength cells with a spectrophotometric procedure (Clayton and Byrne, DSR I, 1993). pH is reported in the 
total scale at 25 ºC (pHST25). The precision was estimated to ±0.0012 by measuring replicates from the same Niskin bottle. Regarding the accuracy, the 
theoretical pH25T value for the 117 CRM batch using the dissociation constants from Mehrbach et al. (LO, 1973) refitted by Dickson and Millero (DSR, 1987) 
is 7.9424. Replicate pH measurements along the cruise on CRMs are lower than the theoretical value by 0.0099  pH units. An internal consistency analysis showed 
that this correction should not be applied. Taken from Report (2) and publication (3).

Total Inorganic Carbon:
Samples were taken in either 250 or 500 ml borosilicate bottles, which are filled after the oxygen samples and immediately poisoned with saturated HgCl2
(100 or 200 μL, respectively). A small headspace is allowed in the DIC bottle for the water to expand. The stoppers were greased with Apiezon L and sealed with 
a rubber band and collar. Samples were analyzed at GEOMAR (Kiel) using a SOMMA system. The accuracy was checked by running certified reference material 
(CRM, batch 108 & 135). The precision of the analysis was checked from replicate analysis  ± 0.9 μmol kg−1. Taken from Report (2).