Summary of Pacific Ocean Survey Cruises
The following table summarizes the analytical techniques, PIs, sample volumes, and shore-based analysis for TALK; PIs and analysis temperatures for fCO2; PIs and sample volumes for pH analysis during the Pacific Ocean survey cruises.
Section | TALK Analysis Technique | TALK P.I. | Sample Vol (mL) | Shore-based Std. Dev. (µmol/kg) | n | cfCO2 Analysis Technique | fCO P.I.2 | Analysis Temperature (°C) | eAnnotation | pH Analysis Technique | pH P.I. | Sample Vol (mL) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
P8S | Potentiometric | Shitashima | 50 | 4.3 | 17 | NDa | ND | ND | ND | Potentiometric | Shitashima | 30 |
P9 | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND | ND |
P10 | Potentiometric | Sabine | 100 | ND | ND | ND | ND | ND | ND | ND | ND | ND |
P13 | Potentiometric | Guenther/Keeling | 91 | ND | ND | ND | ND | ND | ND | ND | ND | ND |
P14N | Potentiometric | Millero | 200 | ND | ND | ND | ND | ND | ND | Spectraphotomtric | Winn | 30 |
P14S15S | Potentiometric | Millero | 200 | ND | ND | GC/Small | Wanninkhof | 20 | WG20 | Spectraphotomtric | Byrne | 10 |
P15N | Potentiometric | Wong | 203 | ND | ND | ND | ND | ND | ND | ND | ND | ND |
EQS92 | Potentiometric | Millero | 200 | ND | ND | IR | Wanninkhof | 20 | fWI20 | Spectraphotomtric | Byrne | 10 |
P16C | Potentiometric | Guenther/Keeling | 91 | ND | ND | ND | ND | ND | ND | ND | ND | ND |
P16N | ND | ND | ND | ND | ND | ND | ND | ND | ND | Spectraphotomtric | Byrne | 10 |
P16S17S | Potentiometric | Goyet | 100 | 3.2 | 12 | GC/Large | Takahashi | 20 | T20 | ND | ND | ND |
P16A17A | ND | ND | ND | ND | ND | GC/Large | Takahashi | d>42.5S=4 <42.5S=20 | T4/T20 | ND | ND | ND |
P17C | Potentiometric | Goyet | 100 | 9.0 | 24 | ND | ND | ND | ND | ND | ND | ND |
P17N | bPotentiometric | Goyet | 100 | ND | ND | ND | ND | ND | ND | ND | ND | ND |
CGC91 | ND | ND | ND | ND | ND | ND | ND | ND | ND | Spectraphotomtric | Byrne | 10 |
P17E19S | ND | ND | ND | ND | ND | GC/Large | Takahashi | 4 | T4 | ND | ND | ND |
P18 | Potentiometric | Millero | 200 | ND | ND | IR | Wanninkhof | 20 | fWI20 | Spectraphotomtric | Byrne | 10 |
P19C | ND | ND | ND | ND | ND | GC/Large | Takahashi | d>45.5S=4 <45.5S=20 | T4/T20 | ND | ND | ND |
P2 | bPotentiometric | Ono | 150 | ND | ND | ND | ND | ND | ND | Potentiometric | Ono | 150 |
P21 | Potentiometric | Millero | 200 | ND | ND | ND | ND | ND | ND | Spectraphotomtric/ gPotentiometric | Millero | 30 |
P31 | Potentiometric | Winn | 200 | ND | ND | ND | ND | ND | ND | Spectraphotomtric | Winn | 30 |
P6 | ND | ND | ND | ND | ND | GC | ND | ND | ND | ND | ND | ND |
S4P | ND | ND | ND | ND | ND | GC/Large | Takahashi | 4 | T20 | ND | ND | ND |
SR3S4 | Potentiometric | Tilbrook | 210 | ND | ND | ND | ND | ND | ND | ND | ND | ND |
aND=No Data
bCRM's not analyzed
cIR=infrared analyzer with samples in 500ml volumetric flasks (Wanninkhof and Thoning, 1993); GC/small=GC with 120ml bottles (Neill et al., 1996); GC/large=GC with samples in 500ml volumetric flasks (Chipman et al., 1993)
dTemperature varied according to surface water temperature
eAnnotations used in Section 2.3
fSuspected to have anomalously low fCO2 at high fCO2 (= >700 µatm)
gEastern section of P21 analyzed using potentiometric technique
Last modified: 2024-09-03T18:01:02Z